Gated equilibrium radionuclide ventriculography is frequently used to measure the left ventricular ejection fraction. We report a case of unilateral breast activity resulting in significant underestimation of the left ventricular ejection fraction, which mimicked a left ventricular aneurysm, pseudoaneurysm, or an intrathoracic vascular mass. Unilateral breast uptake, in the absence of gastric activity, was presumed because of increased blood pool in the lactating breast, a finding not previously reported in the literature. This case is also presented to emphasize the importance of localizing abnormalities based on a review of tomographic images or images taken in at least 2 orthogonal projections.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.