Abstract

The persistent presence of pathogenic bacteria is one of the main obstacles to wound healing. Detection of wound bacteria relies on sampling methods, which delay confirmation by several days. However, a novel handheld fluorescence imaging device has recently enabled real-time detection of bacteria in wounds based on their intrinsic fluorescence characteristics, which differ from those of background tissues. This device illuminates the wound with violet (405 nm) light, causing tissues and bacteria to produce endogenous, characteristic fluorescence signals that are filtered and displayed on the device screen in real-time. The resulting images allow for rapid assessment and documentation of the presence, location, and extent of fluorescent bacteria at moderate-to-heavy loads. This information has been shown to assist in wound assessment and guide patient-specific treatment plans. However, proper image interpretation is essential to assessing this information. To properly identify regions of bacterial fluorescence, users must understand: (1) Fluorescence signals from tissues (e.g., wound tissues, tendon, bone) and fluids (e.g., blood, pus); (2) fluorescence signals from bacteria (red or cyan); (3) the rationale for varying hues of both tissue and bacterial fluorescence; (4) image artifacts that can occur; and (5) some potentially confounding signals from non-biological materials (e.g., fluorescent cleansing solutions). Therefore, this tutorial provides clinicians with a rationale for identifying common wound fluorescence characteristics. Clinical examples are intended to help clinicians with image interpretation—with a focus on image artifacts and potential confounders of image interpretation—and suggestions of how to overcome such challenges when imaging wounds in clinical practice.

Highlights

  • Bacteria is a clinical challenge in acute and chronic wounds [1] which can delay or entirely prevent wound healing [2,3,4,5]

  • By visualizing bacterial fluorescence signals in real-time, images can reveal not just the presence of bacteria but the spatial pattern of bacterial burden. This essentially creates a map of bacteria in the wound that could be used by the clinician for targeted sampling, cleaning, debridement, and other wound therapies [18,19,21,23,24]

  • The largest application of this fluorescence imaging device to date is the visualization of bacteria within and around wounds

Read more

Summary

Introduction

Bacteria is a clinical challenge in acute and chronic wounds [1] which can delay or entirely prevent wound healing [2,3,4,5]. By visualizing bacterial fluorescence signals in real-time, images can reveal not just the presence of bacteria but the spatial pattern of bacterial burden. This essentially creates a map of bacteria in the wound that could be used by the clinician for targeted sampling, cleaning, debridement, and other wound therapies [18,19,21,23,24]. The clinician authors of this paper were some of the earliest adopters of this technology and have each imaged thousands of wounds with this device They share clinical examples, their experiences surrounding the use of this device to image wounds, and information on the interpretation of MolecuLight i:X fluorescence images

How Does the MolecuLight i:X Work?
Evidence for Bacterial Detection
Image Interpretation
Tissue Fluorescence
Characteristic
Bacterial Fluorescence
Methods to to Minimize
Summary
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call