The failure mechanism of in-service fiber reinforced plastic (FRP) rod used in composite insulators is studied experimentally; the integrity of Electrical/Chemical Resistance (ECR) of glass fibers in an epoxy-resin matrix of FRP rod used in transmission composite insulator is the subject of study. FRP Rods are subjected to extreme conditions of aging: the results of leakage current analysis, physical inspection, and corresponding Fourier Transform Infrared Spectroscopy (FTIR) strongly support the reason for the failure of FRP rods under operating condition. The entry of water inside the rod-silicone rubber interface, accompanied by arcing, rise in temperature cause considerable damage and hence failure in the operation of rods. Some interesting results of laboratory aging/failures are compared with field failure samples, also a laboratory method to evaluate failures of FRP rods is proposed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.