Abstract
The underpotential deposition (UPD) of Pb, Bi, Cu, and Cd has been examined on polycrystalline Au in 0.1 M HClO 4 . The Au film electrode was attached to an oscillating quartz crystal microbalance (QCM) mounted in an electrochemical cell. The coverage of the UPD layer on the Au surface is calculated from the frequency change of the QCM as a function of potential. Coverages are in good agreement with previous estimates obtained using other techniques. The electrosorption valencies (γ) have been calculated from the charge to coverage ratios obtained from the QCM. Values for the four metals, Pb (γ = 2.0), Bi (γ = 2.7), Cu (γ =1.4). and Cd (γ = 1.6 to 2.0), are similar to those previously reported. These experiments indicate that the QCM is a quantitative tool for examining monolayer and sub-monolayer metal deposits.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Electroanalytical Chemistry and Interfacial Electrochemistry
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.