Abstract
Objective To assess the validity of corneal power measurement and standard intraocular lens power (IOLP) calculation after photorefractive keratectomy (PRK). Design Nonrandomized, prospective, cross-sectional, clinical study. Participants A total of 31 eyes of 21 females and 10 males with a mean age at the time of surgery of 32.3 ± 6.6 years (range, 24.4–49.5 years). Intervention Subjective refractometry, standard keratometry, TMS-1 corneal topography analysis, and pachymetry were performed before and 15.8 ± 10.4 months after PRK for myopia (n = 24, −1.5 to −8.0 diopters [D], mean −5.4 ± 1.9 D) or myopic astigmatism (n = 7, sphere −2.0 to −7.5 D, mean −4.4 ± 1.9 D; cylinder −1.0 to −3.0 D, mean −1.9 ± 0.7 D). The IOLP calculations were done using two different formulas (SRK/T and HAIGIS). Main outcome measures Keratometric power (K) and topographic simulated keratometric power (TOPO) as measured (K meas, TOPO meas) and as calculated according to the change of power of the anterior corneal surface or according to the spherical equivalent change after PRK (K calc, TOPO calc), IOLP for emmetropia, and postoperative ametropia for calculated corneal powers were assessed in a model. Results After PRK, mean K meas and TOPO meas were significantly greater (0.4–1.4 D, maximum 3.3 D) than mean KR calc and TOPO calc ( P < 0.0001). On average, the relative flattening of the cornea after PRK was underestimated by 14% to 30% (maximum, 83%) depending on the method of calculation. The mean theoretical IOLP after PRK ranged from +17.4 D (SRK/T, TOPO meas) to +20.9 D (HAIGIS, K calc) depending on the calculation method for corneal power and IOLP calculation formula used. For both formulas, IOLP values using keratometric readings were significantly higher (>1 D) than IOLP values using topographic readings ( P < 0.0001). The theoretically induced mean refractive error after cataract surgery ranged from +0.4 to +1.4 (maximum, +3.1) D. Corneal power overestimation and IOLP underestimation correlated significantly with the spherical equivalent change after PRK ( P = 0.001) and the intended ablation depth during PRK ( P = 0.004). Conclusions To avoid underestimation of IOLP and hyperopia after cataract surgery following PRK, measured corneal power values must be corrected. The calculation method using spherical equivalent change of refraction at the corneal plane seems to be the most appropriate method. In comparison with this method, direct power measurements underestimate corneal flattening after PRK by 24% on average. Use of conventional topography analysis seems to increase the risk of error. However, because this study is retrospective and theoretical, there is still a need for a large prospective investigation to validate the authors’ findings.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.