Abstract

The paper addresses the problem of decreasing the overshoot for underdamped second-order systems. A new technique to control the overshoot is proposed, which is based on Posicast control and proportional integral and derivative (PID) control, which performs switching between two controllers. The aim is to use open-loop feedforward control to increase tracking performance and PID control to deal with disturbance rejection. It has been shown that the proposed control scheme can have some advantages over the classical approaches without switching capabilities.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.