Abstract

An inter-laboratory comparison has been made in situ with the participation of 8 laboratories. The operators measured airborne and impact sound insulation of 7 partitions according to the ISO 140 standards and some additional guidelines. Variations of sound insulation, and their components, have been analyzed. In addition, field measurements of sound insulation in 40 building cases were compared to calculations according to EN 12354 (-1, -2). Safety margins for predictions of 3 dB are recommended for calculation of heavy building partitions, with respect to an estimated risk of 5% being disapproved by a sample measurement in situ.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.