Abstract

Abstract The betterment of turbine performance plays a prime role in all future transportation and energy production systems. Precise uncertainty quantification of experimental measurement of any performance differential is therefore essential for turbine development programs. In this paper, the uncertainty analysis of loss measurements in a high-pressure turbine vane is presented. Tests were performed on a stator geometry at engine representative conditions in a new annular turbine module called BRASTA (big rig for annular stationary turbine analysis) located within the Purdue Experimental Turbine Aerothermal Lab. The aerodynamic probes are described, with emphasis on their calibration and uncertainty analysis, first considering single point measurement, followed by the spatial averaging implications. The change of operating conditions and flow blockage due to measurement probes are analyzed using computational fluid dynamics, and corrections are recommended on the measurement data. The test section and its characterization are presented, including calibration of the sonic valve. The sonic valve calibration is necessary to ensure a wide range of operation in Mach and Reynolds. Finally, the vane data are discussed, emphasizing their systematic and stochastic uncertainty.