Abstract

Due to the lack of analysis and research on the performance of different uncertainty evaluation methods in the field of wind speed measurement, it is difficult to choose the most favorable uncertainty evaluation method in the specific wind speed measurement, which will affect the efficiency and accuracy of results. In view of the above situation, this study applied three commonly used uncertainty evaluation methods (conventional GUM method, correlation GUM method and MCM method) to the uncertainty evaluation of wind speed measurement, and analyzed the performance of different methods to provide technical support for specific applications. Firstly, taking the pitot tube wind speed measurement system as an example, the principle and model of wind speed measurement are introduced; Secondly, explain the steps and processes of the above three methods for evaluating uncertainty; Finally, taking a 10 m/s wind speed measurement as an example, the above three methods were used (The correlation GUM method incorporates the correlation between wind tunnel stability and uniformity in its evaluation) to evaluate the uncertainty of wind speed measurement in the Pitot tube wind speed measurement system, and the evaluation results were verified and compared accordingly. The following results were obtained:1) The three uncertainty evaluation methods are all applicable to the evaluation of wind speed measurement uncertainty in this field; 2) The accuracy of evaluation results: MCM method > correlation GUM > conventional GUM, among which correlation GUM method effectively improves the accuracy of uncertainty U95 by 23 % compared to conventional GUM method; 3) Evaluation method operability: MCM method > conventional GUM > correlated GUM. Therefore, we suggest that, when evaluating the uncertainty of wind speed measurement, the MCM method should be given priority when there are high requirements for accuracy and operability. When there are difficulties in the use and promotion of MCM, but there is a high requirement for accuracy, the correlation GUM method can be used. When the accuracy requirement is not high and the calculation is not too complicated, the conventional GUM method can be used.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.