Abstract

The concentrator standard conditions are defined in the standard IEC 62670-1. Those conditions demand for spectral conditions equivalent to AM1.5d as described in IEC 60904-3. The power output of CPV modules has to be rated at the concentrator standard conditions and thus at AM1.5d spectral irradiance. According to IEC standard 62670-3 the prevailing spectral conditions have to be characterized using spectral matching ratios (SMR). The SMR values have to be within three percent of unity to allow for standardized power ratings. The SMR values are calculated from component cell sensor readings. The most commonly used component cells are based on lattice-matched triple-junction cell structures with bandgaps of 1.9, 1.4 and 0.7 eV. In this work, the usage of these component cells for power ratings on CPV modules equipped with other types of multi-junction cells is investigated. This investigation is based on representative power outputs of CPV modules. These power outputs were calculated using i) the spectral...