Abstract

Eight main circulation pumps (MCPs) are employed for the cooling water forced circulation through the RBMK-1500 reactor at the Ignalina nuclear power plant (NPP). There have been a few events when one or more MCPs were inadvertently tripped. This paper presents investigation of a one MCP trip event and all MCPs’ trip events at Ignalina NPP. Thermal-hydraulic analysis was conducted using the best estimate system code RELAP5/MOD3.3. Uncertainty and sensitivity analysis of flow energy loss in different parts of the main circulation circuit (MCC), initial conditions and code-selected models was performed. Such analysis allows to estimate the influence of separate parameters on the calculation results and find those modelling parameters that have the largest impact on the investigated events. Uncertainty analysis indicates that natural circulation provides adequate cooling in the case of all MCPs tripped, and that the reactor is reliably cooled by forced circulation in the case of a single tripped MCP. On the basis of this analysis, recommendations for the further improvement of model are developed.