Abstract

Abstract An uncertainty analysis for steady-state thermal transmission properties determined by the National Institute of Standards and Technology (NIST) 1016 mm guarded-hot-plate apparatus is presented for fibrous-glass blanket and expanded polystyrene board. The uncertainties are presented for the guarded-hot-plate apparatus in the single-sided mode of operation covering specimen heat flows from 0.5 to 5 W. The relative expanded uncertainties for thermal resistance increase from 1 % to 3.5 % for thicknesses of 25.4 to 254 mm, respectively. Although these uncertainties have been developed for two thermal insulation materials, the results are indicative of other insulation materials measured at a mean temperature near 297 K (23.9°C). This assessment of uncertainties is of particular interest for users of ASTM C177-04 test method that operate similar apparatus at low heat flows (i.e., near or less than 1 W). Implications for laboratories that develop secondary standards from NIST calibrations are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.