Abstract
Although deviations in the measurement of acoustic parameters should be lower than the subjectively perceivable change in the corresponding parameter measured, this study reflects that directionality of sound sources could cause wide audience areas to break away from this criterion at high frequencies, even when using dodecahedron loudspeakers which meet the requirements of the ISO 3382 standard. The directivity of four different acoustic sources was measured and the influence of its accurate orientation spatially quantified in five enclosures for speech and music. By means of simulation software, the number of receivers affected by uncertainties greater than difference limens was established.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.