Abstract

Classical aerosol physics predicts that it is impossible to observe noticeable values of the unattached fraction of decay products of thoron at typical concentrations of aerosol particles. The experimental data have shown that the unattached fraction of the thoron decay products in a monazite storage facility is in the range 0.3-0.6. This effect is caused by local increase in air exchange near the inlet of the sampling device at high 220Rn concentrations. It was found that a dynamic shift between the unattached and attached thoron decay products is also observed in the worker's breathing zone at a high concentration of thoron. The 212Pb unattached fraction in worker's breathing zone was ~0.4. It demonstrates that when evaluating inhalation exposure to the products of the decay of thoron, it is necessary to take into account the increase of the 212Pb unattached fraction in the worker's breathing zone.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.