Abstract

Neonates with congenital diaphragmatic hernia (CDH) often require placement of lines and tubes for supportive therapy. The resulting altered anatomy can result in diagnostic errors when interpreting the location of support lines and tubes such as UVCs (umbilical venous catheters). The purpose of this study was to evaluate the effect of CDH on UVC position and to evaluate the accuracy at which radiologists describe the position on chest radiographs. During a 5-year period, 406 chest radiographs performed within 7days of birth in infants with congenital diaphragmatic hernia were identified and reviewed for the following data: presence of UVC, location of catheter tip (cavoatrial junction, intracardiac, intrahepatic or umbilical vein), and location of CDH (right or left). The radiologic report of the UVC tip location for each case was then reviewed individually to determine the adequacy of interpretation. Inadequate reports were classified as incorrect (the wrong location of the catheter tip was reported), no mention (the location of the catheter tip was in a suboptimal location but not mentioned), and not specified (the precise location of the catheter tip was not clearly stated in the report when the tip was in a suboptimal location). A total of 60 infants were identified as having CDH (56 on the left, 4 on the right). The most common location for an incorrectly placed UVC was the contralateral chest, accounting for 26.7% (16/60) of the infants, followed by an abdominal intrahepatic location (16.7%) and the umbilical vein (8.3%). Thirty percent (120/406) of the chest radiograph reports were found to be inadequate regarding the interpretation of the location of the catheter tip. The majority of the inadequate reports (48/406, 11.8%) did not specify when the catheter tip was in a suboptimal location. In 37 reports (9.1%), the location of the catheter tip was reported incorrectly, and no mention of the catheter location was made in 35 reports (8.6%). The location of an UVC in an infant with Bochdalek hernia can pose a diagnostic challenge because of the altered anatomy and change in the expected course of the catheter. Familiarity with the altered anatomy and vigilance of the various abnormal locations in which UVCs can be placed can help optimize management for the child and reduce morbidity and mortality.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call