Abstract

This study presents the results of ultraviolet radiation measurement in a truncated compound parabolic concentrator. The measurements were performed by using of a portable ultraviolet sensor both inside and outside the concentrator without the presence of receiver, under direct and diffuse solar radiation, to calculate the real value of the concentration factor of ultraviolet radiation. The truncated compound parabolic concentrator was designed in Solid Works and built via 3D printing, with a theoretical concentration factor of 4.6. This study showed the differences in the form of the ultraviolet radiation when measurements were made under direct radiation and diffuse solar radiation. These differences are important when measurements were made along the concentrator profile, at different heights within the concentrator and, also, along it. Finally, a concentration factor of 3.3 and 1.4 were calculated on a sunny and a cloudy days, respectively. These values correspond to a concentration efficiency of 71.7 and 31.3%, respectively, against the theoretical value of 4.6 proposed in the design.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.