In this study, we developed an ultrathin filtering membrane with slit-shaped pores which can achieve circulating tumor cell (CTC) separation from whole blood with high performance (high capture efficiency, high white blood cell (WBC) depletion, and high viability). The silicon nitride (Si3N4) filtering membrane was fabricated via the standard microfabrication technology, which can be easily scaled up to mass-production. 6 μm was determined as the optimum width of the filtering pores to better separate CTCs in whole blood, which can reach a high capture efficiency of ∼96%. Meanwhile, the filtering membrane with a high porosity of 34% demonstrated high WBC depletion (∼99.99%). Furthermore, the ultrathin (thickness: 200 nm) Si3N4 membrane facilitated the capture of CTCs with high viability (∼90%). Finally, the microfluidic chip was successfully applied to separate CTCs in whole blood samples from cancer patients and used for molecular examination. These results indicate that this microfluidic chip facilitates the clinical application of CTC-based liquid biopsy technology.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.