Abstract

A new visualization and recording method used to assess and quantitate autogenic high-velocity motions in myocardial walls to provide a new description of cardiac function is described. The regional motion display (RMD) is based on high-speed difference ultrasound B-mode images and spatiotemporal processing to record propagating events (PEs). Sixteen normal participants and one patient with cardiac amyloidosis were imaged at rates of 500-1000/s using the Duke Phased Array Scanner, T5. RMDs were generated using difference images and spatially integrating these to display velocity as function of time along a cardiac wall. In normal participants, RMDs revealed four discrete PEs with average onset timing with respect to the QRS complex of -31.7, +46, +365 and +536 ms. The late diastolic PE propagated apex to base in all participants at an average velocity of 3.4 m/s by the RMD. The RMD of the amyloidosis patient revealed significant changes in the appearance of PEs compared with normal participants. The late diastolic PE propagated at 5.3 m/s from apex to base. All four PEs lagged the average timing of normal participants. The RMD method reliably reveals PEs as discrete events and successfully allows reproducible measurement of PE timing and the velocity of at least one PE. The RMD method is applicable to live, clinical high-speed studies and may offer a new approach to characterization of cardiac function.