Abstract

Abstract High-Intensity Focused Ultrasound (HIFU) is an alternative tumour therapy with the ability for non-invasive thermal ablation of tissue. For a safe application, the heat deposition needs to be monitored over time, which is currently done with Magnetic Resonance Imaging. Ultrasound (US) based monitoring is a promising alternative, as it is less expensive and allows the use of a single device for both therapy and monitoring. In this work, a method for spatial and temporal US thermometry has been investigated based on simulation studies and in-vitro measurements. The chosen approach is based on the approximately linear dependence between temperature and speed of sound (SoS) in tissue for a given temperature range. By tracking the speckles of successive B-images, the possibility of detecting local changes in SoS and therefore in temperature is given. A speckle tracking algorithm was implemented for 2D and 3D US thermometry using a spatial compounding method to reduce artifacts. The algorithm was experimentally validated in an agar-based phantom and in porcine tissue for temperature rises up to △ 8°C. We used a focusing single element US transducer as therapeutic probe, a linear (/matrix array) transducer with 128 (/32∙32) elements for imaging and thermocouples for validation and calibration. In all experiments, both computational and in-vitro, we succeeded in monitoring the thermal induced SoS changes over time. The in-vitro measurements were in good agreement with the simulation results and the thermocouple measurements (rms temperature difference = 0.53 °C, rms correlation coefficient = 0. 96).

Highlights

  • Liver cancer has the third lowest survival rate among oncologic diseases [1]

  • [2] An associated problem concerns the need for monitoring and regulating the High-Intensity Focused Ultrasound (HIFU)-induced heat deposition in a costeffective and patient-friendly way

  • Ultrasound (US) thermometry meets the criteria as it allows the use of a single device for both therapy and monitoring

Read more

Summary

Introduction

Liver cancer has the third lowest survival rate among oncologic diseases [1]. The standard therapeutic procedures are associated with high risk of morbidity and mortality. Ultrasound (US) thermometry meets the criteria as it allows the use of a single device for both therapy and monitoring. It is widely available and offers high spatial and temporal resolution. We studied a method for 2D and 3D US thermometry, that allows the determination of HIFUinduced temperature changes in biological tissue. In-vitro experiments were performed based on an agar-phantom and porcine tissue. For validation of the algorithm and the in-vitro results based on the agar-phantom, two computational model were used. For the in-vitro measurements based on porcine tissue, calibration experiments were conducted, allowing the validation via thermocouples. The suitability of the algorithm for 3D will be verified

Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.