Abstract

The aim of this investigation was to evaluate the role of ultrasonography in avoiding cranial misplacement of the tracheostomy tube and tracheal ring fractures during percutaneous dilatational tracheostomy (PDT). The tracheas of 26 consecutive ICU patients who had undergone PDT but who later died were removed en bloc at autopsy. The tracheas were opened along the membranous portion and the condition of tracheal rings and the site of tracheostomy macroscopically evaluated. The patients were divided in two groups: group A with 15 patients who underwent "blind" PDT and group B with 11 patients who underwent ultrasound-guided PDT. In five (33%) patients from group A, autopsy revealed that the tracheostomy tube was placed between the cricoid cartilage and the first tracheal ring (cranial misplacement) and in six (43%) patients a fracture of one tracheal ring was found. Cranial misplacement of the tracheostomy tube in patients from group B was not found (P < 0.05) and four (36%) patients had a broken tracheal ring (P = NS). The authors maintain that by using ultrasound-guided PDT cranial misplacement of the tracheostomy tube may be entirely avoided.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.