Abstract

Ultrasound (US) based classification systems exist for the stratification of thyroid nodules based on the risk for malignancy. This systematic review aimed to assess the evidence for the performance of US-based thyroid nodule classification systems through correlation with fine needle aspiration biopsy (FNAB). PubMed and Scopus were searched using keywords that included ‘ultrasound classification’, ‘thyroid nodules’, ‘fine needle aspiration’, and ‘malignancy’. Inclusion criteria were as follows: studies/reviews reporting on US imaging for the classification of thyroid nodules. Exclusion criteria were as follows: no comparison between US imaging findings and histology reports based on FNAB, no full English text available/accessible. The database searches identified 66 publications. After evaluation, 12 studies met the inclusion criteria. Two US-based classification systems for thyroid nodules were assessed: the Thyroid Imaging Reporting and Data System (TIRADS) and the American Thyroid Association (ATA) guidelines. For TIRADS, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) ranged from 70.6% to 97.4%, 29.3% to 90.4%, 23.3% to 64.3%, and 87.1% to 99.0%, respectively. The median sensitivity, specificity, PPV, and NPV for TIRADS was 90.0%, 57.4%, 49.0%, and 91.0%, respectively. One study comparing TIRADS with the ATA guidelines demonstrated that TIRADS was superior in terms of sensitivity, whereas the ATA guidelines were superior in terms of specificity and PPV. The high sensitivity and NPV of the US-based TIRADS classification system have excellent utility for correctly classifying nodules as positive for malignant disease and for predicting the absence of malignant disease. The paucity of studies assessing the ATA guidelines highlights avenues for further research comparing TIRADS with other systems of thyroid nodule classification.

Highlights

  • BackgroundHigh-resolution ultrasound (US) is the gold standard test for the identification of thyroid nodules

  • This study assessed the literature on US-based thyroid nodule classification systems, which demonstrated that Thyroid Imaging Reporting and Data System (TIRADS) has utility at classifying thyroid nodules

  • The poor positive predictive value (PPV) of TIRADS may be associated with an excess number of fine needle aspiration biopsy (FNAB) of benign nodules and represents a source of procedural risk, reduced cost-effectiveness, and unnecessary discomfort and concern for the patient

Read more

Summary

Introduction

BackgroundHigh-resolution ultrasound (US) is the gold standard test for the identification of thyroid nodules. Because of a lack of correlation between clinical symptoms and malignancy, the American Association of Clinical Endocrinologists recommends that all nodules smaller than 10 mm or any suspicious nodules on US imaging should be investigated further using FNAB. This recommendation is based on studies that established that prognosis is inversely related to nodule size [2,3]. Guidelines have been developed in order to permit US imaging to be used for the identification and stratification of nodules based on the risk of malignancy [4,5,6,7,8,9,10]. The decision to perform FNAB should be based on the risk of malignancy rather than the size of the nodule per se

Objectives
Methods
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call