Abstract

Endovascular balloon occlusion of the aorta (EBOA) increases proximal arterial pressure but may also induce life-threatening ischemic complications. Although partial REBOA (P-REBOA) mitigates distal ischemia, it requires invasive monitoring of femoral artery pressure for titration. In this study, we aimed to titrate P-REBOA to prevent high-degree P-REBOA using ultrasound assessment of femoral arterial flow. Proximal (carotid) and distal (femoral) arterial pressures were recorded, and perfusion velocity of distal arterial pressures was measured by pulse wave Doppler. Systolic and diastolic peak velocities were measured among all ten pigs. Total REBOA was defined as a cessation of distal pulse pressure, and maximum balloon volume was documented. The balloon volume (BV) was titrated at 20% increments of maximum capacity to adjust the degree of P-REBOA. The distal/proximal arterial pressure gradient and the perfusion velocity of distal arterial pressures were recorded. Proximal blood pressure increased with increasing BV. Distal pressure decreased with increasing BV, and distal pressure sharply decreased by > 80% of BV. Both systolic and diastolic velocities of the distal arterial pressure decreased with increasing BV. Diastolic velocity could not be recorded when the BV of REBOA was > 80%. The diastolic peak velocity in the femoral artery disappeared when %BV was > 80%. Evaluation of the femoral artery pressure by pulse wave Doppler may predict the degree of P-REBOA without invasive arterial monitoring.