Abstract

Chen CP, Wong AM, Hsu C-C, Tsai W-C, Chang C-N, Lin S-C, Huang Y-C, Chang C-H, Tang SF. Ultrasound as a screening tool for proceeding with caudal epidural injections. Objective To study the anatomical structure of the sacral hiatus using ultrasound. Based on the sonographic images of the sacral hiatus, the feasibility of caudal epidural injection can then be assessed. Design Case-controlled study. Setting Rehabilitation outpatient clinic in a tertiary medical center. Participants Patients (N=47; 20 women, 27 men) with low back pain and sciatica who were to receive caudal epidural injection treatments were recruited into this study. Interventions Sonographic images of the sacral hiatus were obtained from all the patients. An ultrasound machine capable of examining musculoskeletal tissues with real-time linear-array ultrasound transducer was used to measure the distance between the anterior wall and posterior wall of the sacral hiatus (diameter of the sacral hiatus) and the distance between bilateral cornua. Main Outcome Measures Diameter of the sacral canal and distance between bilateral cornua measured in millimeters. Results The mean diameter of the sacral canal was measured to be 5.3±2.0mm in our recruited patients. The mean distance between bilateral cornua was measured to be 9.7±1.9mm. Caudal epidural injections failed in 7 patients. In these 7 patients, 4 had very small diameter of the sacral canal (1.6, 1.2, 1.4, and 1.5mm). In 1 man, sonographic images revealed a closed sacral hiatus (no sacral canal diameter can be measured). Two patients revealed flow of fresh blood into the syringe while checking for the escape of cerebrospinal fluid after the needles were inserted into the sacral canal. For safety reasons, steroid injections were not performed in these 2 patients. Conclusions Ultrasound may be used as an effective screening tool for caudal epidural injections. Anatomic variations of the sacral hiatus can be clearly observed using ultrasound. Sonographic images indicating a closed sacral canal and sacral diameters ranging from 1.2 to 1.6mm may suggest a higher failure rate in caudal epidural injection.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.