Abstract
Direct-coupled (DC) and catheter-cooled (CC) ultrasound applicator configurations were evaluated for high-temperature ultrasound interstitial thermal therapy (USITT) using computer simulations, acoustic beam measurements, and in vivo temperature measurements. The DC devices consist of 2.2-mm diameter tubular ultrasound transducers encapsulated within a thin biocompatible plastic coating, which can be inserted directly into the tissue. The CC devices incorporate 1.5-mm diameter tubular transducers, which are inserted within 2.2to 2.4-mm diameter plastic implant catheters and require an integrated water-cooling scheme. Simulated transient temperature profiles and cumulative thermal dose distributions indicate that each of these applicator configurations can produce target temperatures greater than 50 degrees C and corresponding thermal doses greater than 300 to 600 equivalent minutes at 43 degrees C (EM(43 degrees C)) within 5 min at a radial depth of 1 to 1.5 cm in moderately perfused tissues. Theoretical investigations of air-cooling implemented within DC applicators demonstrated a significant enhancement of thermal penetration compared with non-cooled DC applicators, thus approaching performance attainable with CC devices. Temperature distributions achieved with DC and CC applicators in vivo were in agreement with theoretical calculations and further demonstrate that the devices are practical, sufficient power output levels can be obtained, and the angular heating profiles can be shaped or directed to protect non-targeted critical normal tissues. This preliminary study demonstrates that these interstitial ultrasound applicators have potential to provide controlled thermal coagulation and necrosis of small target regions and deserve further investigation and development for possible implementation in the treatment of benign and cancerous lesions in sites such as prostate, liver, and brain.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.