Abstract

Ultrasonography is widely used to diagnose carpal tunnel syndrome (CTS), a common peripheral neuropathy, but the reported diagnostic accuracy varies. This meta-analysis focused on the diagnostic test accuracy of ultrasonography for diagnosing CTS. Structured searches of PubMed for 1990–2010 were done and the data were extracted and meta-analyzed by pooling estimates of sensitivity, specificity, likelihood ratios and diagnostic odds ratios. Diagnostic performance was also judged by using a summary receiver operating characteristic curve. Twenty-eight trials involving 3995 wrists were included. A greater cross-sectional area (CSA) of the median nerve at the carpal tunnel inlet (CSA-I) and a greater flattening ratio at the level of the hamate were seen in CTS wrists than in control wrists. A CSA-I ≥9 mm2 is the best single diagnostic criterion, with a diagnostic odds ratio of 40.4 (sensitivity 87.3%, specificity 83.3%).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.