Abstract

Gastric tubes are commonly used for the administration of drugs and tube feeding for people who are unable to swallow. Feeding via a tube misplaced in the trachea can result in severe pneumonia. Therefore, the confirmation of tube placement in the stomach after tube insertion is important. Recent studies have reported that ultrasonography provides good diagnostic accuracy estimates in the confirmation of appropriate tube placement. Hence, ultrasound could provide a promising alternative to X-rays in the confirmation of tube placement, especially in settings where X-ray facilities are unavailable or difficult to access. To assess the diagnostic accuracy of ultrasound for gastric tube placement confirmation. We searched the Cochrane Library (2016, Issue 3), MEDLINE (to March 2016), Embase (to March 2016), National Institute for Health Research (NIHR) PROSPERO Register (to May 2016), Aggressive Research Intelligence Facility Databases (to May 2016), ClinicalTrials.gov (to May 2016), ISRCTN registry (May 2016), World Health Organization International Clinical Trials Registry Platform (to May 2016) and reference lists of articles, and contacted study authors. We included studies that evaluated the diagnostic accuracy of naso- and orogastric tube placement confirmed by ultrasound visualization using X-ray visualization as the reference standard. We included cross-sectional studies, and case-control studies. We excluded case series or case reports. Studies were excluded if X-ray visualization was not the reference standard or if the tube being placed was a gastrostomy or enteric tube. Two review authors independently assessed the risk of bias and extracted data from each of the included studies. We contacted authors of the included studies to obtain missing data. We identified 10 studies (545 participants and 560 tube insertions) which met our inclusion criteria.No study was assigned low risk of bias or low concern in every QUADAS-2 domain. We judged only three (30%) studies to have low risk of bias in the participant selection domain because they performed ultrasound after they confirmed correct position by other methods.Few data (43 participants) were available for misplacement detection (specificity) due to the low incidence of misplacement. We did not perform a meta-analysis because of considerable heterogeneity of the index test such as the difference of echo window, the combination of ultrasound with other confirmation methods (e.g. saline flush visualization by ultrasound) and ultrasound during the insertion of the tube. For all settings, sensitivity estimates for individual studies ranged from 0.50 to 1.00 and specificity estimates from 0.17 to 1.00. For settings where X-ray was not readily available and participants underwent gastric tube insertion for drainage (four studies, 305 participants), sensitivity estimates of ultrasound in combination with other confirmatory tests ranged from 0.86 to 0.98 and specificity estimates of 1.00 with wide confidence intervals.For the studies using ultrasound alone (four studies, 314 participants), sensitivity estimates ranged from 0.91 to 0.98 and specificity estimates from 0.67 to 1.00. Of 10 studies that assessed the diagnostic accuracy of gastric tube placement, few studies had a low risk of bias. Based on limited evidence, ultrasound does not have sufficient accuracy as a single test to confirm gastric tube placement. However, in settings where X-ray is not readily available, ultrasound may be useful to detect misplaced gastric tubes. Larger studies are needed to determine the possibility of adverse events when ultrasound is used to confirm tube placement.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call