Abstract

Background: Ultrasonic shears (LCS) are used increasingly for laparoscopic splenectomy. So far however, all investigators use vascular staplers or clips for section of the main splenic artery and vein. Methods: After several trials the authors started to use the ultrasonic triple welding technique in open surgery to occlude major vessels of 5 to 8 mm by 10-mm LCS. In June 1997 the authors introduced triple welding into laparoscopic splenectomy to mobilize the complete spleen by LCS. Results: There was no hemorrhage in 23 laparoscopic splenectomies performed exclusively by LCS and no complications except 1 port site hernia. Conclusions: Laparoscopic splenectomy entirely by reusable LCS without clips and stapler is a safe, simple, and inexpensive technique. Moreover, the policy of “leaving nothing back” is an attractive strategy in endoscopic pediatric surgery. J Pediatr Surg 37:614-616. Copyright 2002, Elsevier Science (USA). All rights reserved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.