Abstract
Ultrasonic wave propagation in deteriorated concrete structures was studied numerically and experimentally. Ultrasonic single-side access immersion pulse-echo and diffuse field measurements were performed in deteriorated concrete structures at 0.5MHz center frequency. Numerically and experimentally it is shown that the undamaged layer thickness in a deteriorated concrete structure is measurable using pulse-echo measurements when the deterioration depth is larger than the wavelength. The signal overlapping, which occurs in the thin deteriorated layers, can be overcome using diffuse field measurements or a pattern matching technique. The ultrasonic experimental data were shown to be in good agreement with the widely used phenolphthalein test for concrete degradation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.