Abstract

Standard ultrasound measurements were performed by two observers in 40 third-trimester fetuses. Observers were blinded to the results of the measurements. Estimated fetal weight (EFW) was calculated using two published formulae. The intra-observer standard deviation for EFW, assessed using one-way analysis of variance, was < 75 g for both observers. The 95% prediction intervals for inter-observer comparisons of EFW, calculated using the limits of agreement method, were -187.3 g to 139.8 g, and -159.9 g to 124.3 g, using the two formulae. The results suggest that measurements of EFW are reproducible. The prediction interval is comparable to the weekly fetal weight increment in normal fetuses.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.