Abstract

The effect of surface roughness on the adhesion behavior of the electroless nickel seed layer deposited on the glass substrate is reported. Localized regions having varying surface roughness were created in glass substrates by changing the abrasive size and ultrasonic power ratings. Electroless nickel as a seed layer and electroplated copper having thickness up to 8 µm were deposited. Scotch-tape test revealed good adhesion between electroless nickel and glass in the roughened regions. After the tape-test, the intact copper area was higher for samples with higher surface roughness due to the presence of multiple interlocked regions that prevented adhesion failure. Thickness-dependent adhesion characteristics were observed in which the intact area reduces with increasing copper thickness, and complete failure took place when copper thickness exceeded 8 μm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.