Abstract

Nitrosamine impurities are potentially genotoxic which are considered under cohort of concern as per ICH M7 guidelines and need to be controlled at trace levels during quantification in drug substances and drug products for safe human consumption. Recent regulatory requirements also suggest the need to have highly sensitive analytical methods for the accurate quantification of Nitrosamine impurities. In this paper we have presented simple, rapid and ultra-sensitive LC-MS/MS method for six potential genotoxic nitrosamine impurities: N-Nitroso dimethyl amine (NDMA), N-Nitroso diethyl amine (NDEA), N-Nitroso Ethyl Iso propylamine (NEIPA), N-Nitroso-N-methyl-4-aminobutyric acid (NMBA) N-Nitroso diisopropylamino (NDIPA) and N-Nitroso dibutyl amine (NDBA) with a LOQ of 0.004 ppm. Chromatographic separation is achieved using Zorbax SB C18 150 × 3.0 mm, 3.5 μ column with 0.1% formic acid in water as mobile phase A and 0.1% formic acid in methanol as mobile phase B at a flow rate of 0.3 ml/min using gradient mode of elution at a total run time of 18 minutes. Six nitrosamine impurities are successfully ionized and quantified in positive mode of atmospheric pressure chemical ionization (APCI) using multiple reaction monitoring (MRM). Method validation is performed as per ICH guidelines evaluating the limit of quantification and detection and found to give good S/N ratios with good linearity range of 0.002 - 2 ppm with regression coefficient >0.99 for all the six nitrosamine impurities. Method recoveries are established using three-step sample preparation protocol and are found to be satisfactory within 80% - 120%. The method can be used routinely applied for the detection of Nitrosamines in Telmisartan at a concentration of 1.5 ng/ml (0.03 ppm with respect to telmisartan concentration of 50 mg/ml).

Highlights

  • Pharmaceutical impurities are unwanted chemicals that can form during synthesis of active pharmaceutical ingredients or degradation and can arise during storage conditions, excipient interactions or contaminations [1] [2] [3]

  • In this paper we have presented simple, rapid and ultra-sensitive LC-MS/MS method for six potential genotoxic nitrosamine impurities: N-Nitroso dimethyl amine (NDMA), N-Nitroso diethyl amine (NDEA), N-Nitroso Ethyl Iso propylamine (NEIPA), N-Nitroso-Nmethyl-4-aminobutyric acid (NMBA) N-Nitroso diisopropylamino (NDIPA) and N-Nitroso dibutyl amine (NDBA) with a Limit of quantification (LOQ) of 0.004 ppm

  • Recent trends in pharmaceutical industry regarding the multiple recalls of different therapeutic category drugs by various regulatory agencies like United States Food and Drug Administration (USFDA) and European Medicines Agency (EMA) due to presence of different nitrosamine impurities show the importance of eliminating the impurities for safe human consumption [7] [8] [9]

Read more

Summary

Introduction

Pharmaceutical impurities are unwanted chemicals that can form during synthesis of active pharmaceutical ingredients or degradation and can arise during storage conditions, excipient interactions or contaminations [1] [2] [3]. Recent trends in pharmaceutical industry regarding the multiple recalls of different therapeutic category drugs by various regulatory agencies like United States Food and Drug Administration (USFDA) and European Medicines Agency (EMA) due to presence of different nitrosamine impurities show the importance of eliminating the impurities for safe human consumption [7] [8] [9]. USFDA and other regulatory agencies have published guidelines for the control of nitrosamine impurities in drug substances and drug products [10]. Multiple analytical methods are published by regulatory agencies for the determination of nitrosamines in various drug substances and drug products. Nitrosamine impurities are screened based on the route of synthesis, starting materials, solvents used, stability of drug substance and drug product

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call