Abstract
This work presents the first demonstration of a cantilever based cholerae sensor. Dynamic force microscopy within atomic force microscope (AFM) is applied to measure the cantilever's resonance frequency shift due to mass of cell bound on microcantilever surface. The Vibrio cholerae O1, a food and waterborne pathogen that caused cholera disease in human, is a target bacterium cell of interest. Commercial gold-coated AFM microcantilevers are immobilized with monoclonal antibody (anti- V. cholerae O1) by self-assembled monolayer method. V. cholerae O1 detection experiment is then conducted in concentrations ranging from 1 × 10 3 to 1 × 10 7 CFU/ml. The microcantilever-based sensor has a detection limit of ∼1 × 10 3 CFU/ml and a mass sensitivity, Δ m/Δ F, of ∼146.5 pg/Hz, which is at least two orders of magnitude lower than other reported techniques and sufficient for V. cholerae detection in food products without pre-enrichment steps. In addition, V. cholerae O1 antigen–antibody binding on microcanilever is confirmed by scanning electron microscopy. The results demonstrate that the new biosensor is promising for high sensitivity, uncomplicated and rapid detection of V. cholerae O1.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.