Abstract

In the present work, a novel strategy based on new carbon nanotube (CNT) and polypyrrole (ppy) composite modified electrode for the simultaneous determination of the isomers of Amaranth (E123) and Ponceau 4R (E124) was proposed. Due to the increasing dispersibility and effective surface area of the CNT caused by decoration of ppy to the CNT, the proposed electrode exhibited excellent electrochemical sensitivity and high selectivity toward the oxidation of Amaranth and Ponceau 4R. The linear response ranges for Amaranth and Ponceau 4R were 5.0×10−9M–5.0×10−7M, and 8×10−9M–1×10−6M and corresponding detection limits as low as 5.0×10−10M and 1.0×10−9M, respectively.This proposed method was successfully applied in the detection of Ponceau 4R and Amaranth in fruit drink samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.