Abstract
The ultramicrodetermination of cyanocobalamin (9 ng/g) in elemental diet containing 46 kinds of compounds, with concentrations at least 50–10 6 times higher than that of cyanocobalamin, was performed by Sep-Pak C 18 purification and concentration of cyanocobalamin followed by HPLC with detection at 550 nm. The method is simple, rapid, sensitive and reproducible. The calibration graph was linear in the range of 0-0.2 μg. The recovery of cyanocobalamin was over 95% by the standard addition method. There was good agreement between the cyanocobalamin concentrations indicated and found.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.