Abstract

PurposePhantom studies in CT emphysema quantification show that iterative reconstruction and deep learning-based noise reduction (DLNR) allow lower radiation dose. We compared emphysema quantification on ultra-low-dose CT (ULDCT) with and without noise reduction, to standard-dose CT (SDCT) in chronic obstructive pulmonary disease (COPD). MethodForty-nine COPD patients underwent ULDCT (third generation dual-source CT; 70ref-mAs, Sn-filter 100kVp; median CTDIvol 0.38 mGy) and SDCT (64-multidetector CT; 40mAs, 120kVp; CTDIvol 3.04 mGy). Scans were reconstructed with filtered backprojection (FBP) and soft kernel. For ULDCT, we also applied advanced modelled iterative reconstruction (ADMIRE), levels 1/3/5, and DLNR, levels 1/3/5/9. Emphysema was quantified as Low Attenuation Value percentage (LAV%, ≤-950HU). ULDCT measures were compared to SDCT as reference standard. ResultsFor ULDCT, the median radiation dose was 84 % lower than for SDCT. Median extent of emphysema was 18.6 % for ULD-FBP and 15.4 % for SDCT (inter-quartile range: 11.8–28.4 % and 9.2 %–28.7 %, p = 0.002). Compared to SDCT, the range in limits of agreement of emphysema quantification as measure of variability was 14.4 for ULD-FBP, 11.0–13.1 for ULD-ADMIRE levels and 10.1–13.9 for ULD-DLNR levels. Optimal settings were ADMIRE 3 and DLNR 3, reducing variability of emphysema quantification by 24 % and 27 %, at slight underestimation of emphysema extent (−1.5 % and −2.9 %, respectively). ConclusionsUltra-low-dose CT in COPD patients allows dose reduction by 84 %. State-of-the-art noise reduction methods in ULDCT resulted in slight underestimation of emphysema compared to SDCT. Noise reduction methods (especially ADMIRE 3 and DLNR 3) reduced variability of emphysema quantification in ULDCT by up to 27 % compared to FBP.

Highlights

  • Lung tissue densitometry is a common method for quantifying emphysema on CT in patients with chronic obstructive pulmonary disease (COPD) [1,2,3,4]

  • Our study shows that ultra-lowdose CT (ULDCT) reduced radiation dose by 84 % compared to standard-dose CT in COPD patients

  • advanced modelled iterative reconstruction (ADMIRE) 3 and deep learningbased noise reduction (DLNR) 3 provided an optimal balance for emphysema quantification in ULDCT, with decrease in variability by up to 27 % compared to filtered backprojection (FBP), at slight underestimation of emphysema extent

Read more

Summary

Introduction

Lung tissue densitometry is a common method for quantifying emphysema on CT in patients with chronic obstructive pulmonary disease (COPD) [1,2,3,4]. These CT-derived estimates of emphysema severity correlate well with pulmonary function test results, pathology results, and mortality rates [5,6,7,8,9]. Methods are being investigated to reduce CT image noise to levels similar to SDCT [3,4,12]

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.