Abstract

We report on measurements of the frequency noise of a highly stabilised injection locked Nd:YAG laser. We use a nested loop frequency stabilisation scheme to achieve a loop gain of ∼1×10 6 at Fourier frequencies around 1 kHz with frequency actuation applied only to the master oscillator. A frequency noise level of ∼ 2×10 −5 Hz Hz −1/2 was measured for the master laser around this frequency using an independent, narrow line width, suspended analyser cavity. Furthermore we demonstrate that the frequency noise performance of the injection locked slave laser is identical to that of the master oscillator to this level. This performance is very close to the frequency noise specification for gravitational wave detection by GEO 600.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.