Abstract

This study quantifies in vivo ischemic stroke brain injuries in rats using ultrahigh-field single-scan MRI methods to assess variations in apparent diffusion coefficients (ADCs). Magnitude and diffusion-weighted spatiotemporally encoded imaging sequences were implemented on a 21.1 T imaging system, and compared with spin-echo and echo-planar imaging diffusion-weighted imaging strategies. ADC maps were calculated and used to evaluate the sequences according to the statistical comparisons of the ipsilateral and contralateral ADC measurements at 24, 48, and 72 h poststroke. Susceptibility artifacts resulting from normative anatomy and pathological stroke conditions were particularly intense at 21.1 T. These artifacts strongly distorted single-shot diffusion-weighted echo-planar imaging experiments, but were reduced in four-segment interleaved echo-planar imaging acquisitions. By contrast, nonsegmented diffusion-weighted spatiotemporally encoded images were largely immune to field-dependent artifacts. Effects of stroke were apparent in both magnitude images and ADC maps of all sequences. When stroke recovery was followed by ADC variations, spatiotemporally encoded, echo-planar imaging, and spin-echo acquisitions revealed statistically significant increase in ADCs. Consideration of experiment duration, image quality, and mapped ADC values provided by spatiotemporally encoded demonstrates that this single-shot acquisition is a method of choice for high-throughput, ultrahigh-field in vivo stroke quantification.