Abstract

The aim of this study was to investigate diagnostic accuracy and impact on patient management of an ultrafast (4:33 minutes/5 sequences) brain magnetic resonance imaging (MRI) protocol for the detection of intracranial pathologies in acute neurological emergencies. Four hundred forty-nine consecutive emergency patients with acute nontraumatic neurological symptoms were evaluated for this institutional review board-approved prospective single-center trial. Sixty patients (30 female, 30 male; mean age, 61 years) with negative head CT were included and underwent emergency brain MRI at 3 T subsequent to CT. MRI included the ultrafast protocol (ultrafast-MRI; sag T1 GRE, ax T2 TSE, ax T2 TSE Flair, ax T2* EPI-GRE, ax DWI SS-EPI; TA, 5 minutes) and an equivalent standard-length protocol (TA, 15 minutes) as reference standard. Two blinded board-certified neuroradiologists independently analyzed the MRI with regard to image quality (1, nondiagnostic; 2, substantial artifacts; 3, satisfactory; 4, minor artifacts; 5, no artifacts) and intracranial pathologies. Sensitivity and specificity for the detection of intracranial pathologies were calculated accordingly. Ninety-three additional intracranial lesions (acute ischemia, n = 21; intracranial hemorrhage/microbleeds, n = 27; edema, n = 2; white matter lesion, n = 38; chronic infarction, n = 3; others, n = 2) were detected by ultrafast-MRI, whereas 101 additional intracranial lesions were detected by the standard-length protocol (acute ischemia, n = 24; intracranial hemorrhage/microbleeds, n = 32; edema, n = 2; white matter lesion, n = 38; chronic infarction, n = 3; others, n = 2). Image quality was equivalent to the standard-length protocol. Ultrafast-MRI demonstrated high diagnostic accuracy (sensitivity, 0.939 [0.881-0.972]; specificity, 1.000 [0.895-1.000]) for the detection of intracranial pathologies. MRI led to a change in patient management in 10% compared with the initial CT. Ultrafast-MRI enables time-optimized diagnostic workup in acute neurological emergencies at high sensitivity and specificity compared with a standard-length protocol, with direct impact on patient management. Ultrafast MRI protocols are a powerful tool in the emergency setting and may be implemented on various scanner types based on the optimization of individual acquisition parameters.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call