Abstract

T2 relaxation time measurement is a powerful tool to distinguish signal components in porous media. As T2 weighting is generally achieved by spin-echo based methods, it is very challenging to capture very short T2 relaxation time components, approximately 1 ms, with high resolution spatial encoding. It is especially challenging when T2 relaxation times of the other signal components are not known a priori. We propose a method, combining ultrashort echo time (UTE) imaging with multiple spin echo refocusing, to generate a series of images with T2 weighting. The T2 decay curves for each image voxel were extracted, and multiple T2 relaxation components were quantitatively evaluated. The method has been applied to a fast relaxation system, namely, moisture content in wood samples to differentiate cell wall (bound) water and cell cavity (lumen) water.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.