Abstract

Generally, in a waveguide-based humidity sensors, increasing the relative humidity (RH) causes the cladding refractive index (RI) to increase due to cladding water absorption. However, if graphene oxide (GO) is used, a reverse phenomenon is seen due to a gap increase in graphene layers. In this paper, this interesting property is applied in order to fabricate differential humidity sensor using the difference between RI of reduced GO (rGO) and nano-anatase TiO2 in a chip. First, a new approach is proposed to prepare high quality nano-anatase TiO2 in solution form making the fabrication process simple and straightforward. Then, the resulted solutions (TiO2 and GO) are effortlessly drop casted and reduced on SU8 two channels waveguide and extensively examined against several humid conditions. Investigating the sensitivity and performance (response time) of the device, reveals a great linearity in a wide range of RH (35% to 98%) and a variation of more than 30 dB in transmitted optical power with a response time of only ~0.7 sec. The effect of coating concentration and UV treatment are studied on the performance and repeatability of the sensor and the attributed mechanisms explained. In addition, we report that using the current approach, devices with high sensitivity and very low response time of only 0.3 sec can be fabricated. Also, the proposed device was comprehensively compared with other state of the art proposed sensors in the literature and the results were promising. Since high sensitivity ~0.47dB/%RH and high dynamic performances were demonstrated, this sensor is a proper choice for biomedical applications.

Highlights

  • Monitoring humidity is essential is many industries and applications [1]

  • In this research, an optical method is proposed to implement a humidity sensor using nano-anatase TiO2 particles and reduced graphene oxide

  • An optical humidity sensor was presented based on the effect of evanescent field in anastase TiO2 nanoparticle and reduced graphene oxide coatings

Read more

Summary

Introduction

Monitoring humidity is essential is many industries and applications [1]. It is vital in medical and chemical industries to monitor patients breathing profile and control the chemical processes [2, 3]. A new approach is proposed to prepare high quality nano-anatase TiO2 in solution form making the fabrication process simple and straightforward. We report that using the current approach, devices with high sensitivity and very low response time of only 0.3 sec can be fabricated.

Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call