Abstract

A simple reverse-phase method for the selective quantification of pitavastatin calcium (PIT) and its related substances was developed. The method demonstrated an excellent separation between PIT and each of 15 impurities (including its isomers and degradants) within a short run time of 12 min by HPLC. A rapid resolution similar to that of UHPLC was achieved using high flow rate on superficially porous C18 stationary phase. A synergistic combination of quality by design approach and use of a superficially porous column delivered a HPLC method with ultra-high performance. Forced degradation studies proved the method to be highly specific (mass balance > 98 %) and the structures of major degradation products were proposed based on LC–MS analysis. The results of validation proved the method to be highly precise (%RSD 0.999) and sensitive (LOQ ≤ 0.02 % and LOD ≤ 0.005 %) for all the impurities and drug. Use of multivariate analysis helped to incorporate high robustness in the method. The method is valuable for quantification of PIT and its related substances in both drug substance and oral solid dosage form.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.