Abstract

The corrosive marine environment is a threat to the ultimate strength of steel sandwich structures. Therefore, ultimate strength experiments were carried out in three-point bending for beams with different corrosion exposure times, i.e. one and two years. Standard laser-welded web-core sandwich beams are studied and different corrosion protection systems are considered. The beams experienced general corrosion. The thickness reduction in unprotected plates and laser welds is around the typical 0.1 mm/year. This led to an ultimate strength reduction of 10% and 17% for beams with exposure times of one and two years, respectively. The experimental ultimate strength is in agreement with finite element simulations. The ultimate strength was maintained for the beams protected with coating or closed-cell polyurethane (PU) foam.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.