Abstract

In order to apply precast decks to continuous composite bridges, several experiments and analytical studies were performed. From many previous studies, design criteria for crack controls in transverse joints of prefabricated slabs were confirmed. These considerations were needed for serviceability. The bridges which satisfy service limit states, also, should be evaluated for ultimate strengths to define limit states. In this paper, experimental and analytical studies of two-span continuous composite bridges with open box girder section were conducted. Cracking, yielding and ultimate loads were evaluated and compared with the test results for design of continuous composite bridges with precast decks. To evaluate yielding loads of continuous bridges, an uncracked section method considering moment redistribution which is defined in EUROCODE 4, was considered. In calculation of ultimate strengths, full or partial shear connection and sectional classes which were defined in EUROCODE or AASHTO LRFD specifications were considered. Also, through numerical analysis considering material nonlinearities, moment–curvature relationship and moment redistributions were estimated.