Abstract

ABSTRACT
 
 ABSTRACT This study aims to determine the capacity of the resonance machine capacity 63 kn which has the influence of strain in analyzing the static loading stress on the coupon test. The study used a coupon test specimen with a predetermined dimension, using eight strain gauges in a vertical direction, where the response of the strain gauge system was fast enough to sense dynamic strain with a frequency greater than 100 kHz. The strain gauge used was a strain gauge for gauge bridges where the application is easy. The results obtained show that there is no strain and stress on specimens that point to numbers below -100 to 100, but this number is considered good because it does not exceed the number specified in the tolerance category the third step measurement results are used for knowing the ability to reset, relative error and machine linearity and the expected deviation value is not more than 1%.
 Keywords: resonance machine, coupon test, strain gauge, specimen

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.