Abstract

Elagolix sodium is a gonadotropin-releasing hormone (GnRH) receptor antagonist that inhibits endogenous GnRH signaling by competitively binding to GnRH receptors in the pituitary gland to treat moderate to severe pain associated with endometriosis. To keep the safety and quality of the drug, a fast quantitative method by reversed-phase ultrahigh-performance liquid chromatography coupled with tandem mass spectrometry has been developed and validated for the identification, assay and estimation of potential genotoxic impurities trimethyl phosphate and triisopropyl phosphate in commercial batches of this active pharmaceutical ingredient in accordance with International Conference on Harmonization guidelines Q2 and M7. The method was validated by assessing specificity, sensitivity, linearity, the limit of quantification and detection, accuracy, precision and robustness for above analytes at a very low concentration, whose quantification and detection limits reached to 24 and 4.8pg/ml, respectively, and the total run time for a single injection was 6min.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.