Abstract: The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-r ise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unre inforced beam-column specimen and two reinforced specimens with U-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of U-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the p recast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Sin ce the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of th is specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member m ainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D, agreed with the experimental result based on t he elastic analysis of Midas-Zen by using the largest loading from experiment.Keywords: Infilled, Seismic resistant method, Precast concrete, Wall panel, Retrofit, Quasi static test, Shear
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of the Korea institute for structural maintenance and inspection
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.