Abstract
An orifice-couple consisting of two segmental or eccentric orifices installed in series in the direction of flow was devised for component flow rate measurements in horizontal gas-liquid two-phase flow. One of the orifices takes its opening at the lower side of the tube cross section and the other at the upper side. Because the phase distribution in horizontal two-phase flow is, generally, asymmetric to the tube axis, the flow passing through the orifice-couple generates such two pressure differences as governed by the independent relationships between flow rate and pressure difference. The new device was applied to froth, separate and annular flow in the test tube of 26.0 mm in inner diameter. The experimental results show that the orifice-couple is effectively used to measure the component flow rate in every flow pattern tested, and that a suitable orifice is one of segmental opening with area ratio of 0.4∼0.6.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.