Abstract
In JT-60U divertor plasmas, deuterium Balmer-series line emission has been measured with a wide-spectral-band spectrometer, which has 92 viewing chords with a ˜1cm spatial resolution. Two-dimensional spatial distribution of the Balmer line intensities has been reconstructed using a computer tomography technique (maximum entropy method). In an inner-detached and outer-attached divertor plasma, the intensity of Dβ and Dγ lines were stronger above the strike point in the inner divertor and near the strike point in the outer divertor. The ratio of the Dγ line intensity to the Dβ line intensity was 0.3 - 0.5 above the strike point in the inner divertor and 0 - 0.2 near the strike point in the outer divertor. It suggested that the line emission were attributed to the plasma recombination above the strike point in the inner divertor and the plasma ionization near the strike point in the outer divertor.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.