Abstract

Unintentional or accidental extubation is an undesirable complication in the mechanically ventilated patient. This is particularly dangerous in high-risk patients who are on neuromuscular blocking agents or positive end-expiratory pressure or are difficult to reintubate. This article identifies some of the factors resulting in intentional extubation as well as measures taken to prevent them. A protocol was developed and utilized in Catholic Medical Center. The results of a two-year study reveal a reduction of the incidence from an initial 12% to 5% and a reduction of high-risk extubations from five to an incidence of three. The investigator also assembled an airway system consisting of low pressure cuff endotracheal tube with a pressure monitoring device and several adapters along with a tube fixation system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.