Abstract
This note proposes a new method for snapshot analysis of water distribution systems based on the commonly used gradient method. The proposed method uses a secant (intersecting the head-loss function in two points) instead of a tangent to approximate the pipe head-loss function. A theoretical model is developed for the flow range in which the secant approximates the head-loss function without exceeding a given allowable error. This scheme allows a tradeoff to be made between the allowable error and the number of iterations required to achieve convergence. The proposed method is applied to an example network to illustrate its application and benefits. It is argued that the number of iterations required to find a solution can be reduced significantly in both snapshot and extended-period simulations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.